Energy Performance Certificate

Flat 3, 70 Harrowby Road, NG31 9DS

EPC Report

Energy rating

Current: 58 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 89 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 Current: 89 90 Potential: 90
Field Value
LMK KEY 3590-0347-0022-2509-3053
ADDRESS1 Flat 3
ADDRESS2 70 Harrowby Road
ADDRESS3
POSTCODE NG31 9DS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2025-10-04
LOCAL AUTHORITY E07000141
CONSTITUENCY E14001253
COUNTY
LODGEMENT DATE 2025-11-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 89
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 170
ENERGY CONSUMPTION POTENTIAL 170
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 16
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 45
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 823
HEATING COST POTENTIAL 526
HOT WATER COST CURRENT 536
HOT WATER COST POTENTIAL 338
TOTAL FLOOR AREA 45
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 3, 70 Harrowby Road
LOCAL AUTHORITY LABEL South Kesteven
CONSTITUENCY LABEL Grantham and Bourne
POSTTOWN GRANTHAM
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2025-11-09 09:23:53
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 18
UPRN 10007262385
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000004
Address display
Nation ew