Energy Performance Certificate

Swallows, Back Drove, Leigh, DT9 6JD

EPC Report

Energy rating

Current: 48 E | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 49 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 61 Potential: 61
Field Value
LMK KEY 3535-8223-4500-0330-3272
ADDRESS1 Swallows
ADDRESS2 Back Drove
ADDRESS3 Leigh
POSTCODE DT9 6JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2025-07-30
LOCAL AUTHORITY E06000059
CONSTITUENCY E14001575
COUNTY
LODGEMENT DATE 2025-07-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 230
ENERGY CONSUMPTION POTENTIAL 163
CO2 EMISSIONS CURRENT 7.8
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 145
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 2197
HEATING COST POTENTIAL 1579
HOT WATER COST CURRENT 300
HOT WATER COST POTENTIAL 301
TOTAL FLOOR AREA 165
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Swallows, Back Drove, Leigh
LOCAL AUTHORITY LABEL Dorset
CONSTITUENCY LABEL West Dorset
POSTTOWN SHERBORNE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2025-07-31 20:44:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 200000771754
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display