Energy Performance Certificate

10 Chevers Pawen, SS13 3EJ

EPC Report

Energy rating

Current: 4 G | Potential: 24 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 4 G Current: 4 G 24 F Potential: 24 F

Environmental impact (CO₂)

Current: 19 | Potential: 35
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 Current: 19 35 Potential: 35
Field Value
LMK KEY 3512-0326-8090-0823-2222
ADDRESS1 10 Chevers Pawen
ADDRESS2
ADDRESS3
POSTCODE SS13 3EJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 4
POTENTIAL ENERGY EFFICIENCY 24
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-06-27
LOCAL AUTHORITY E07000066
CONSTITUENCY E14001480
COUNTY
LODGEMENT DATE 2022-06-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 19
ENVIRONMENT IMPACT POTENTIAL 35
ENERGY CONSUMPTION CURRENT 650
ENERGY CONSUMPTION POTENTIAL 430
CO2 EMISSIONS CURRENT 9.9
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL 6.6
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 2962
HEATING COST POTENTIAL 2339
HOT WATER COST CURRENT 678
HOT WATER COST POTENTIAL 405
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 90% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Chevers Pawen
LOCAL AUTHORITY LABEL Basildon
CONSTITUENCY LABEL South Basildon and East Thurrock
POSTTOWN BASILDON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2022-06-27 11:02:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100090238803
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display