Energy Performance Certificate

608 Milton Mount, RH10 3DY

EPC Report

Energy rating

Current: 77 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 78 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 84 Potential: 84
Field Value
LMK KEY 3434-2425-8300-0438-8222
ADDRESS1 608 Milton Mount
ADDRESS2
ADDRESS3
POSTCODE RH10 3DY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2024-05-28
LOCAL AUTHORITY E07000226
CONSTITUENCY E14001184
COUNTY
LODGEMENT DATE 2024-05-29
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 148
ENERGY CONSUMPTION POTENTIAL 106
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 126
LIGHTING COST POTENTIAL 126
HEATING COST CURRENT 563
HEATING COST POTENTIAL 375
HOT WATER COST CURRENT 144
HOT WATER COST POTENTIAL 145
TOTAL FLOOR AREA 71
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 17.73
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 608 Milton Mount
LOCAL AUTHORITY LABEL Crawley
CONSTITUENCY LABEL Crawley
POSTTOWN CRAWLEY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-05-29 08:28:42
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10000075320
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew