Energy Performance Certificate

98 Homefield Road, Sileby, LE12 7TQ

EPC Report

Energy rating

Current: 65 D | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 60 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 87 Potential: 87
Field Value
LMK KEY 3419-7074-4002-0401-3102
ADDRESS1 98 Homefield Road
ADDRESS2 Sileby
ADDRESS3
POSTCODE LE12 7TQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-09-04
LOCAL AUTHORITY E07000130
CONSTITUENCY E14001357
COUNTY
LODGEMENT DATE 2024-09-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 269
ENERGY CONSUMPTION POTENTIAL 77
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 48
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 94
HEATING COST CURRENT 1125
HEATING COST POTENTIAL 645
HOT WATER COST CURRENT 156
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 75
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 98 Homefield Road, Sileby
LOCAL AUTHORITY LABEL Charnwood
CONSTITUENCY LABEL Melton and Syston
POSTTOWN LOUGHBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-09-04 13:26:38
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100030447319
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000004
Address display
Nation ew