Energy Performance Certificate

First Floor Flat, 36 High Street, LL57 3AN

EPC Report

Energy rating

Current: 36 F | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 38 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 68 Potential: 68
Field Value
LMK KEY 3290-1874-0022-7403-3043
ADDRESS1 First Floor Flat
ADDRESS2 36 High Street
ADDRESS3
POSTCODE LL57 3AN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-10-03
LOCAL AUTHORITY W06000002
CONSTITUENCY W07000083
COUNTY
LODGEMENT DATE 2024-10-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 536
ENERGY CONSUMPTION POTENTIAL 251
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 93
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 1096
HEATING COST POTENTIAL 510
HOT WATER COST CURRENT 446
HOT WATER COST POTENTIAL 143
TOTAL FLOOR AREA 46
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS First Floor Flat, 36 High Street
LOCAL AUTHORITY LABEL Gwynedd
CONSTITUENCY LABEL Bangor Aberconwy
POSTTOWN BETHESDA
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-10-10 13:08:25
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 200003198528
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew