Energy Performance Certificate

516 Milton Mount, RH10 3DY

EPC Report

Energy rating

Current: 66 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 50 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 65 Potential: 65
Field Value
LMK KEY 3239-7728-3000-0330-8296
ADDRESS1 516 Milton Mount
ADDRESS2
ADDRESS3
POSTCODE RH10 3DY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-08-10
LOCAL AUTHORITY E07000226
CONSTITUENCY E14001184
COUNTY
LODGEMENT DATE 2021-08-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 355
ENERGY CONSUMPTION POTENTIAL 244
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 60
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 107
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 607
HEATING COST POTENTIAL 328
HOT WATER COST CURRENT 242
HOT WATER COST POTENTIAL 189
TOTAL FLOOR AREA 70
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 11.54
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 516 Milton Mount
LOCAL AUTHORITY LABEL Crawley
CONSTITUENCY LABEL Crawley
POSTTOWN CRAWLEY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-08-10 06:41:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10000075310
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew