Energy Performance Certificate

Oakwood, Plovers Barrows, Buxted, TN22 4JP

EPC Report

Energy rating

Current: 75 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 66 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 70 Potential: 70
Field Value
LMK KEY 3235-0423-6500-0473-2202
ADDRESS1 Oakwood
ADDRESS2 Plovers Barrows
ADDRESS3 Buxted
POSTCODE TN22 4JP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-07-07
LOCAL AUTHORITY E07000065
CONSTITUENCY E14001212
COUNTY
LODGEMENT DATE 2025-07-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 137
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 148
LIGHTING COST POTENTIAL 148
HEATING COST CURRENT 2129
HEATING COST POTENTIAL 1918
HOT WATER COST CURRENT 245
HOT WATER COST POTENTIAL 245
TOTAL FLOOR AREA 269
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 30
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Oakwood, Plovers Barrows, Buxted
LOCAL AUTHORITY LABEL Wealden
CONSTITUENCY LABEL East Grinstead and Uckfield
POSTTOWN UCKFIELD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-07-09 21:12:54
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 96
LOW ENERGY FIXED LIGHT COUNT 96
UPRN 10033400757
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew