Energy Performance Certificate

18 Richmond Village, St. Josephs Way, CW5 6TD

EPC Report

Energy rating

Current: 58 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 63 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 65 Potential: 65
Field Value
LMK KEY 3232-2927-4100-0979-3202
ADDRESS1 18 Richmond Village
ADDRESS2 St. Josephs Way
ADDRESS3
POSTCODE CW5 6TD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2022-03-01
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001185
COUNTY
LODGEMENT DATE 2022-03-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 335
ENERGY CONSUMPTION POTENTIAL 314
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 51
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 644
HEATING COST POTENTIAL 319
HOT WATER COST CURRENT 188
HOT WATER COST POTENTIAL 206
TOTAL FLOOR AREA 42
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18 Richmond Village, St. Josephs Way
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Crewe and Nantwich
POSTTOWN NANTWICH
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2022-03-01 14:15:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10013156338
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000002
Address display
Nation ew