Energy Performance Certificate

55 Lionel Oxley House, New Road, RM17 6PP

EPC Report

Energy rating

Current: 39 E | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 25 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 60 Potential: 60
Field Value
LMK KEY 3137-8028-0100-0835-9226
ADDRESS1 55 Lionel Oxley House
ADDRESS2 New Road
ADDRESS3
POSTCODE RM17 6PP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2023-08-25
LOCAL AUTHORITY E06000034
CONSTITUENCY E14001546
COUNTY
LODGEMENT DATE 2023-08-31
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 612
ENERGY CONSUMPTION POTENTIAL 263
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 104
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 208
LIGHTING COST POTENTIAL 146
HEATING COST CURRENT 1555
HEATING COST POTENTIAL 397
HOT WATER COST CURRENT 1131
HOT WATER COST POTENTIAL 1031
TOTAL FLOOR AREA 69
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 9.41
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 55 Lionel Oxley House, New Road
LOCAL AUTHORITY LABEL Thurrock
CONSTITUENCY LABEL Thurrock
POSTTOWN GRAYS
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2023-08-31 09:00:34
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100091300029
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew