Energy Performance Certificate

Flat 71, Northfield House 110-114, Baxter Avenue, SS2 6FG

EPC Report

Energy rating

Current: 45 E | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 42 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 67 Potential: 67
Field Value
LMK KEY 3134-7822-4400-0485-3296
ADDRESS1 Flat 71
ADDRESS2 Northfield House 110-114
ADDRESS3 Baxter Avenue
POSTCODE SS2 6FG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-02-15
LOCAL AUTHORITY E06000033
CONSTITUENCY E14001501
COUNTY
LODGEMENT DATE 2024-11-12
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 610
ENERGY CONSUMPTION POTENTIAL 333
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 103
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 44
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 1030
HEATING COST POTENTIAL 228
HOT WATER COST CURRENT 236
HOT WATER COST POTENTIAL 204
TOTAL FLOOR AREA 30
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.4
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 71, Northfield House 110-114, Baxter Avenue
LOCAL AUTHORITY LABEL Southend-on-Sea
CONSTITUENCY LABEL Southend East and Rochford
POSTTOWN SOUTHEND-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-11-12 13:49:45
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10093164231
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display