Energy Performance Certificate

8 Tindale Terrace, Tindale Fell, CA8 2QJ

EPC Report

Energy rating

Current: 38 F | Potential: 110 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 110 A Potential: 110 A

Environmental impact (CO₂)

Current: 32 | Potential: 101
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 101 Potential: 101
Field Value
LMK KEY 3132-6622-3100-0865-3296
ADDRESS1 8 Tindale Terrace
ADDRESS2 Tindale Fell
ADDRESS3
POSTCODE CA8 2QJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 110
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-02-15
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001152
COUNTY
LODGEMENT DATE 2022-02-21
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 101
ENERGY CONSUMPTION CURRENT 465
ENERGY CONSUMPTION POTENTIAL -30
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 1175
HEATING COST POTENTIAL 464
HOT WATER COST CURRENT 469
HOT WATER COST POTENTIAL 150
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8 Tindale Terrace, Tindale Fell
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Carlisle
POSTTOWN BRAMPTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-02-21 11:35:33
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10009456478
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000002
Address display
Nation ew