Energy Performance Certificate

77 FOREST ROAD, LOUGHTON, IG10 1EE

EPC Report

Energy rating

Current: 1 G | Potential: 25 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 25 F Potential: 25 F

Environmental impact (CO₂)

Current: 1 | Potential: 23
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 23 Potential: 23
Field Value
LMK KEY 3115-4089-0002-0529-9402
ADDRESS1 77 FOREST ROAD
ADDRESS2 LOUGHTON
ADDRESS3
POSTCODE IG10 1EE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 25
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-01-29
LOCAL AUTHORITY E07000072
CONSTITUENCY E14001226
COUNTY
LODGEMENT DATE 2021-03-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 23
ENERGY CONSUMPTION CURRENT 1111
ENERGY CONSUMPTION POTENTIAL 543
CO2 EMISSIONS CURRENT 13.5
CO2 EMISS CURR PER FLOOR AREA 231
CO2 EMISSIONS POTENTIAL 6.8
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 2500
HEATING COST POTENTIAL 1411
HOT WATER COST CURRENT 600
HOT WATER COST POTENTIAL 353
TOTAL FLOOR AREA 58
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 77 FOREST ROAD, LOUGHTON
LOCAL AUTHORITY LABEL Epping Forest
CONSTITUENCY LABEL Epping Forest
POSTTOWN LOUGHTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-03-03 15:58:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100090504345
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew