Energy Performance Certificate

20 Buttercup Close, EX12 2XB

EPC Report

Energy rating

Current: 91 B | Potential: 97 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 B Current: 91 B 97 A Potential: 97 A

Environmental impact (CO₂)

Current: 92 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 Current: 92 97 Potential: 97
Field Value
LMK KEY 3032-8028-4200-0569-8276
ADDRESS1 20 Buttercup Close
ADDRESS2
ADDRESS3
POSTCODE EX12 2XB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 91
POTENTIAL ENERGY EFFICIENCY 97
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-08-31
LOCAL AUTHORITY E07000040
CONSTITUENCY E14001291
COUNTY
LODGEMENT DATE 2023-06-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 92
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 50
ENERGY CONSUMPTION POTENTIAL -3
CO2 EMISSIONS CURRENT 0.3
CO2 EMISS CURR PER FLOOR AREA 8
CO2 EMISSIONS POTENTIAL 0.0
LIGHTING COST CURRENT 99
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 602
HEATING COST POTENTIAL 499
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 122
TOTAL FLOOR AREA 41
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double, known data
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 63% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20 Buttercup Close
LOCAL AUTHORITY LABEL East Devon
CONSTITUENCY LABEL Honiton and Sidmouth
POSTTOWN SEATON
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2023-06-28 12:13:07
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100040189624
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000009
Address display
Nation ew