Energy Performance Certificate

46c Brondesbury Road, NW6 6BS

EPC Report

Energy rating

Current: 56 D | Potential: 58 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 58 D Potential: 58 D

Environmental impact (CO₂)

Current: 50 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 52 Potential: 52
Field Value
LMK KEY 3020-9232-0126-3206-0433
ADDRESS1 46c Brondesbury Road
ADDRESS2
ADDRESS3
POSTCODE NW6 6BS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 58
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-07-17
LOCAL AUTHORITY E09000005
CONSTITUENCY E14001435
COUNTY
LODGEMENT DATE 2024-07-19
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 330
ENERGY CONSUMPTION POTENTIAL 317
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 145
LIGHTING COST POTENTIAL 107
HEATING COST CURRENT 1552
HEATING COST POTENTIAL 1510
HOT WATER COST CURRENT 192
HOT WATER COST POTENTIAL 192
TOTAL FLOOR AREA 62
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 50
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.72
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 46c Brondesbury Road
LOCAL AUTHORITY LABEL Brent
CONSTITUENCY LABEL Queen's Park and Maida Vale
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-07-19 16:46:33
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 202126363
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew