Energy Performance Certificate

38 Simpkin Close, Eaton Socon, PE19 8PD

EPC Report

Energy rating

Current: 65 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 61 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 79 Potential: 79
Field Value
LMK KEY 3001-7014-0122-1002-0773
ADDRESS1 38 Simpkin Close
ADDRESS2 Eaton Socon
ADDRESS3
POSTCODE PE19 8PD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2023-03-09
LOCAL AUTHORITY E07000011
CONSTITUENCY E14001512
COUNTY
LODGEMENT DATE 2023-03-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 263
ENERGY CONSUMPTION POTENTIAL 127
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 106
HEATING COST CURRENT 1177
HEATING COST POTENTIAL 1018
HOT WATER COST CURRENT 227
HOT WATER COST POTENTIAL 152
TOTAL FLOOR AREA 64
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38 Simpkin Close, Eaton Socon
LOCAL AUTHORITY LABEL Huntingdonshire
CONSTITUENCY LABEL St Neots and Mid Cambridgeshire
POSTTOWN ST. NEOTS
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2023-03-09 14:07:41
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10000142326
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew