Energy Performance Certificate

Dunrovin, High Road, Wisbech St. Mary, PE13 4RA

EPC Report

Energy rating

Current: 47 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 40 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 61 Potential: 61
Field Value
LMK KEY 2990-2387-0622-1497-3943
ADDRESS1 Dunrovin
ADDRESS2 High Road
ADDRESS3 Wisbech St. Mary
POSTCODE PE13 4RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2024-11-18
LOCAL AUTHORITY E07000010
CONSTITUENCY E14001390
COUNTY
LODGEMENT DATE 2025-04-15
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 241
ENERGY CONSUMPTION POTENTIAL 125
CO2 EMISSIONS CURRENT 8.4
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 137
LIGHTING COST POTENTIAL 137
HEATING COST CURRENT 1626
HEATING COST POTENTIAL 1110
HOT WATER COST CURRENT 178
HOT WATER COST POTENTIAL 120
TOTAL FLOOR AREA 135
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Dunrovin, High Road, Wisbech St. Mary
LOCAL AUTHORITY LABEL Fenland
CONSTITUENCY LABEL North East Cambridgeshire
POSTTOWN WISBECH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-04-15 13:59:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100090080758
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew