Energy Performance Certificate

38 WEST CHILTON TERRACE, CHILTON, DL17 0HH

EPC Report

Energy rating

Current: 48 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 33 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 60 Potential: 60
Field Value
LMK KEY 2982-1911-5202-7840-0200
ADDRESS1 38 WEST CHILTON TERRACE
ADDRESS2 CHILTON
ADDRESS3
POSTCODE DL17 0HH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-12-28
LOCAL AUTHORITY E06000047
CONSTITUENCY E14001382
COUNTY
LODGEMENT DATE 2021-01-04
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 563
ENERGY CONSUMPTION POTENTIAL 305
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 95
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 1434
HEATING COST POTENTIAL 881
HOT WATER COST CURRENT 328
HOT WATER COST POTENTIAL 124
TOTAL FLOOR AREA 87
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38 WEST CHILTON TERRACE, CHILTON
LOCAL AUTHORITY LABEL County Durham
CONSTITUENCY LABEL Newton Aycliffe and Spennymoor
POSTTOWN CHILTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-01-04 10:42:48
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100110475246
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000001
Address display