Energy Performance Certificate

15, The Close, Church Aston, TF10 9JL

EPC Report

Energy rating

Current: 48 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 44 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 76 Potential: 76
Field Value
LMK KEY 2948-8074-7299-0847-5904
ADDRESS1 15, The Close
ADDRESS2 Church Aston
ADDRESS3
POSTCODE TF10 9JL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-01-24
LOCAL AUTHORITY E06000020
CONSTITUENCY E14001543
COUNTY
LODGEMENT DATE 2013-01-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 333
ENERGY CONSUMPTION POTENTIAL 129
CO2 EMISSIONS CURRENT 6.0
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 789
HEATING COST POTENTIAL 497
HOT WATER COST CURRENT 332
HOT WATER COST POTENTIAL 173
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 15, The Close, Church Aston
LOCAL AUTHORITY LABEL Telford and Wrekin
CONSTITUENCY LABEL The Wrekin
POSTTOWN NEWPORT
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-01-25 11:46:11
TENURE Unknown
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 452035357
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew