Energy Performance Certificate

2, Wheatlands Drive, Easington, TS13 4PB

EPC Report

Energy rating

Current: 22 F | Potential: 100 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 100 A Potential: 100 A

Environmental impact (CO₂)

Current: 33 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 75 Potential: 75
Field Value
LMK KEY 2948-3906-7280-4856-4940
ADDRESS1 2, Wheatlands Drive
ADDRESS2 Easington
ADDRESS3
POSTCODE TS13 4PB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 100
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-10-24
LOCAL AUTHORITY E06000003
CONSTITUENCY E14001368
COUNTY
LODGEMENT DATE 2016-10-24
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 558
ENERGY CONSUMPTION POTENTIAL 207
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 94
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 87
HEATING COST CURRENT 2019
HEATING COST POTENTIAL 802
HOT WATER COST CURRENT 445
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 91
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Wheatlands Drive, Easington
LOCAL AUTHORITY LABEL Redcar and Cleveland
CONSTITUENCY LABEL Middlesbrough South and East Cleveland
POSTTOWN SALTBURN-BY-THE-SEA
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-10-24 17:07:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100110088143
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000001
Address display
Nation ew