Energy Performance Certificate

12 VICTORIA COURT, VICTORIA ROAD, RAMSGATE, CT11 8PP

EPC Report

Energy rating

Current: 79 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 82 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 82 Potential: 82
Field Value
LMK KEY 2948-3271-1131-2151-1864
ADDRESS1 12 VICTORIA COURT
ADDRESS2 VICTORIA ROAD
ADDRESS3 RAMSGATE
POSTCODE CT11 8PP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-03-27
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001216
COUNTY
LODGEMENT DATE 2021-03-29
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 127
ENERGY CONSUMPTION POTENTIAL 123
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 244
HEATING COST POTENTIAL 246
HOT WATER COST CURRENT 77
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 63
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.12
FLOOR HEIGHT 2.78
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 VICTORIA COURT, VICTORIA ROAD, RAMSGATE
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL East Thanet
POSTTOWN RAMSGATE
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2021-03-29 19:50:48
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10022962808
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew