Energy Performance Certificate

3 Priory Place, Sporle, PE32 2DT

EPC Report

Energy rating

Current: 58 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 81 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 86 Potential: 86
Field Value
LMK KEY 2914-7221-9836-7197-8116
ADDRESS1 3 Priory Place
ADDRESS2 Sporle
ADDRESS3
POSTCODE PE32 2DT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2025-09-19
LOCAL AUTHORITY E07000143
CONSTITUENCY E14001497
COUNTY
LODGEMENT DATE 2025-09-19
TRANSACTION TYPE Re-mortgaging
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 297
ENERGY CONSUMPTION POTENTIAL 236
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 1
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 1355
HEATING COST POTENTIAL 1194
HOT WATER COST CURRENT 367
HOT WATER COST POTENTIAL 367
TOTAL FLOOR AREA 49
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical extract, decentralised (MEV dc)
ADDRESS 3 Priory Place, Sporle
LOCAL AUTHORITY LABEL Breckland
CONSTITUENCY LABEL South West Norfolk
POSTTOWN KING'S LYNN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-09-19 21:25:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100090778103
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew