Energy Performance Certificate

The Gate House, The Square, CT7 9AB

EPC Report

Energy rating

Current: 77 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 79 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 91 Potential: 91
Field Value
LMK KEY 2908-2079-7222-0157-2974
ADDRESS1 The Gate House
ADDRESS2 The Square
ADDRESS3
POSTCODE CT7 9AB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2013-02-20
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001282
COUNTY
LODGEMENT DATE 2013-02-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 122
ENERGY CONSUMPTION POTENTIAL 39
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 23
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 47
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 320
HEATING COST POTENTIAL 320
HOT WATER COST CURRENT 85
HOT WATER COST POTENTIAL 60
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Gate House, The Square
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL Herne Bay and Sandwich
POSTTOWN BIRCHINGTON
CONSTRUCTION AGE BAND England and Wales: 2007 onwards
LODGEMENT DATETIME 2013-02-20 16:24:43
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 10013309817
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew