Energy Performance Certificate

Flat 2, Harbourside, Capstone Crescent, EX34 9BT

EPC Report

Energy rating

Current: 75 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 79 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 81 Potential: 81
Field Value
LMK KEY 2902-8065-8002-1496-0806
ADDRESS1 Flat 2
ADDRESS2 Harbourside
ADDRESS3 Capstone Crescent
POSTCODE EX34 9BT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-06-11
LOCAL AUTHORITY E07000043
CONSTITUENCY E14001387
COUNTY
LODGEMENT DATE 2025-06-11
TRANSACTION TYPE
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 167
ENERGY CONSUMPTION POTENTIAL 149
CO2 EMISSIONS CURRENT 1.2
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 313
HEATING COST POTENTIAL 278
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 106
TOTAL FLOOR AREA 40
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 2, Harbourside, Capstone Crescent
LOCAL AUTHORITY LABEL North Devon
CONSTITUENCY LABEL North Devon
POSTTOWN ILFRACOMBE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2025-06-11 18:44:39
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10000488282
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000009
Address display
Nation ew