Energy Performance Certificate

28 Carnsmerry, Bugle, PL26 8PX

EPC Report

Energy rating

Current: 35 F | Potential: 55 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 55 D Potential: 55 D

Environmental impact (CO₂)

Current: 39 | Potential: 53
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 53 Potential: 53
Field Value
LMK KEY 2900-4570-0522-0221-3443
ADDRESS1 28 Carnsmerry
ADDRESS2 Bugle
ADDRESS3
POSTCODE PL26 8PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 55
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-04-23
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001508
COUNTY
LODGEMENT DATE 2024-04-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 53
ENERGY CONSUMPTION CURRENT 370
ENERGY CONSUMPTION POTENTIAL 240
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 171
LIGHTING COST POTENTIAL 171
HEATING COST CURRENT 2763
HEATING COST POTENTIAL 2389
HOT WATER COST CURRENT 647
HOT WATER COST POTENTIAL 343
TOTAL FLOOR AREA 97
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood), Room heaters, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28 Carnsmerry, Bugle
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Austell and Newquay
POSTTOWN ST. AUSTELL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-04-24 15:45:04
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100040137464
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew