Energy Performance Certificate

6, Hillside, Manston, DT10 1EY

EPC Report

Energy rating

Current: 35 F | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 27 | Potential: 49
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 49 Potential: 49
Field Value
LMK KEY 2858-9014-7296-5588-8954
ADDRESS1 6, Hillside
ADDRESS2 Manston
ADDRESS3
POSTCODE DT10 1EY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-06-25
LOCAL AUTHORITY E06000059
CONSTITUENCY E14001388
COUNTY
LODGEMENT DATE 2018-06-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 49
ENERGY CONSUMPTION CURRENT 521
ENERGY CONSUMPTION POTENTIAL 291
CO2 EMISSIONS CURRENT 9.1
CO2 EMISS CURR PER FLOOR AREA 88
CO2 EMISSIONS POTENTIAL 5.1
LIGHTING COST CURRENT 124
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 1540
HEATING COST POTENTIAL 1066
HOT WATER COST CURRENT 300
HOT WATER COST POTENTIAL 166
TOTAL FLOOR AREA 103
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Hillside, Manston
LOCAL AUTHORITY LABEL Dorset
CONSTITUENCY LABEL North Dorset
POSTTOWN STURMINSTER NEWTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2018-06-25 12:36:00
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10013219258
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew