Energy Performance Certificate

10 Chapel Court, Chapel Row, NE68 7TD

EPC Report

Energy rating

Current: 64 D | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 40 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 60 Potential: 60
Field Value
LMK KEY 2848-1911-0209-7779-0200
ADDRESS1 10 Chapel Court
ADDRESS2 Chapel Row
ADDRESS3
POSTCODE NE68 7TD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-11-24
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001397
COUNTY
LODGEMENT DATE 2021-12-14
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 518
ENERGY CONSUMPTION POTENTIAL 323
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 88
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 271
HEATING COST POTENTIAL 347
HOT WATER COST CURRENT 623
HOT WATER COST POTENTIAL 205
TOTAL FLOOR AREA 57
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 8
FLOOR HEIGHT 4.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Chapel Court, Chapel Row
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL North Northumberland
POSTTOWN SEAHOUSES
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2021-12-14 13:19:08
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100110770879
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000001
Address display
Nation ew