Energy Performance Certificate

10 Park View Road, W5 2JB

EPC Report

Energy rating

Current: 94 A | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 A Current: 94 A 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 86 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 86 Potential: 86
Field Value
LMK KEY 2847-3933-5209-7565-1204
ADDRESS1 10 Park View Road
ADDRESS2
ADDRESS3
POSTCODE W5 2JB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 94
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-11-24
LOCAL AUTHORITY E09000009
CONSTITUENCY E14001207
COUNTY
LODGEMENT DATE 2025-11-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 48
ENERGY CONSUMPTION POTENTIAL 48
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 145
LIGHTING COST POTENTIAL 145
HEATING COST CURRENT 1314
HEATING COST POTENTIAL 1314
HOT WATER COST CURRENT 246
HOT WATER COST POTENTIAL 246
TOTAL FLOOR AREA 432
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 30
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Park View Road
LOCAL AUTHORITY LABEL Ealing
CONSTITUENCY LABEL Ealing Central and Acton
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 2022 onwards
LODGEMENT DATETIME 2025-11-25 08:48:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 75
LOW ENERGY FIXED LIGHT COUNT 75
UPRN 12091724
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew