Energy Performance Certificate

2 The Belvedere, 2 Picardy Road, DA17 5QH

EPC Report

Energy rating

Current: 73 C | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 76 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 76 Potential: 76
Field Value
LMK KEY 2834-5239-4000-0450-7272
ADDRESS1 2 The Belvedere
ADDRESS2 2 Picardy Road
ADDRESS3
POSTCODE DA17 5QH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2024-01-30
LOCAL AUTHORITY E09000004
CONSTITUENCY E14001229
COUNTY
LODGEMENT DATE 2024-01-30
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 160
ENERGY CONSUMPTION POTENTIAL 160
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 788
HEATING COST POTENTIAL 788
HOT WATER COST CURRENT 232
HOT WATER COST POTENTIAL 232
TOTAL FLOOR AREA 69
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 45
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.70 W/m²K
FLOOR ENERGY EFF Poor
FLOOR ENV EFF Poor
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Average thermal transmittance 1.08 W/m²K
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.16 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 2 The Belvedere, 2 Picardy Road
LOCAL AUTHORITY LABEL Bexley
CONSTITUENCY LABEL Erith and Thamesmead
POSTTOWN BELVEDERE
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2024-01-30 12:47:17
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10094792095
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew