Energy Performance Certificate

Flat 1 26 Fairfield Road, N8 9HG

EPC Report

Energy rating

Current: 34 F | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 39 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 81 Potential: 81
Field Value
LMK KEY 2830-5064-7203-9107-4200
ADDRESS1 Flat 1 26 Fairfield Road
ADDRESS2
ADDRESS3
POSTCODE N8 9HG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2023-07-27
LOCAL AUTHORITY E09000014
CONSTITUENCY E14001293
COUNTY
LODGEMENT DATE 2023-07-28
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 394
ENERGY CONSUMPTION POTENTIAL 114
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 146
LIGHTING COST POTENTIAL 153
HEATING COST CURRENT 3191
HEATING COST POTENTIAL 537
HOT WATER COST CURRENT 185
HOT WATER COST POTENTIAL 248
TOTAL FLOOR AREA 84
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas instantaneous at point of use
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.3
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1 26 Fairfield Road
LOCAL AUTHORITY LABEL Haringey
CONSTITUENCY LABEL Hornsey and Friern Barnet
POSTTOWN London
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-07-28 08:33:41
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 100021177859
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew