Energy Performance Certificate

Apartment 14, SORTING HOUSE, 192 St Ann’s Hill, SW18 2RT

EPC Report

Energy rating

Current: 85 B | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 88 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 88 Potential: 88
Field Value
LMK KEY 2829-3007-6302-9894-3200
ADDRESS1 Apartment 14
ADDRESS2 SORTING HOUSE
ADDRESS3 192 St Ann’s Hill
POSTCODE SW18 2RT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2024-02-22
LOCAL AUTHORITY E09000032
CONSTITUENCY E14001434
COUNTY
LODGEMENT DATE 2024-02-22
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 78
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 0.7
CO2 EMISS CURR PER FLOOR AREA 13
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 258
HEATING COST POTENTIAL 258
HOT WATER COST CURRENT 132
HOT WATER COST POTENTIAL 132
TOTAL FLOOR AREA 50
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.20 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Apartment 14, SORTING HOUSE, 192 St Ann’s Hill
LOCAL AUTHORITY LABEL Wandsworth
CONSTITUENCY LABEL Putney
POSTTOWN London
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2024-02-22 15:25:07
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10096838530
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display