Energy Performance Certificate

BOWNESS HOUSE, MINOR ROAD THROUGH BOWNESS ON SOLWAY FROM BARWISE BROW, BOWNESS ON SOLWAY, CA7 5AF

EPC Report

Energy rating

Current: 6 G | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 6 G Current: 6 G 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 28 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 71 Potential: 71
Field Value
LMK KEY 2815-4999-7482-8381-9466
ADDRESS1 BOWNESS HOUSE
ADDRESS2 MINOR ROAD THROUGH BOWNESS ON SOLWAY FROM BARWISE BROW
ADDRESS3 BOWNESS ON SOLWAY
POSTCODE CA7 5AF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 6
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-01-29
LOCAL AUTHORITY E06000063
CONSTITUENCY E14001424
COUNTY
LODGEMENT DATE 2021-02-26
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 582
ENERGY CONSUMPTION POTENTIAL 186
CO2 EMISSIONS CURRENT 17
CO2 EMISS CURR PER FLOOR AREA 81
CO2 EMISSIONS POTENTIAL 5.7
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 125
HEATING COST CURRENT 6473
HEATING COST POTENTIAL 1481
HOT WATER COST CURRENT 402
HOT WATER COST POTENTIAL 137
TOTAL FLOOR AREA 204
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS BOWNESS HOUSE, MINOR ROAD THROUGH BOWNESS ON SOLWAY FROM BARWISE BROW, BOWNESS ON SOLWAY
LOCAL AUTHORITY LABEL Cumberland
CONSTITUENCY LABEL Penrith and Solway
POSTTOWN BOWNESS ON SOLWAY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-02-26 18:01:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10008820954
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000002
Address display
Nation ew