Energy Performance Certificate

12 Netherhampton Road, SP2 8HE

EPC Report

Energy rating

Current: 23 F | Potential: 51 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 51 E Potential: 51 E

Environmental impact (CO₂)

Current: 34 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 56 Potential: 56
Field Value
LMK KEY 2814-1544-4045-8075-1215
ADDRESS1 12 Netherhampton Road
ADDRESS2
ADDRESS3
POSTCODE SP2 8HE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 51
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2022-09-27
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001460
COUNTY
LODGEMENT DATE 2022-09-27
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 518
ENERGY CONSUMPTION POTENTIAL 297
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 88
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 2309
HEATING COST POTENTIAL 1528
HOT WATER COST CURRENT 238
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 63
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 Netherhampton Road
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL Salisbury
POSTTOWN SALISBURY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2022-09-27 08:48:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100121050641
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew