Energy Performance Certificate

36 GARRETT CLOSE, KINGSCLERE, RG20 5SD

EPC Report

Energy rating

Current: 75 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 71 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 77 Potential: 77
Field Value
LMK KEY 2808-3006-3205-9799-4200
ADDRESS1 36 GARRETT CLOSE
ADDRESS2 KINGSCLERE
ADDRESS3
POSTCODE RG20 5SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-05-20
LOCAL AUTHORITY E07000084
CONSTITUENCY E14001403
COUNTY
LODGEMENT DATE 2021-05-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 168
ENERGY CONSUMPTION POTENTIAL 132
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 134
LIGHTING COST POTENTIAL 82
HEATING COST CURRENT 587
HEATING COST POTENTIAL 535
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 99
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 36
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 36% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.23
PHOTO SUPPLY 20
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36 GARRETT CLOSE, KINGSCLERE
LOCAL AUTHORITY LABEL Basingstoke and Deane
CONSTITUENCY LABEL North West Hampshire
POSTTOWN NEWBURY
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2021-05-20 13:04:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060250674
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew