Energy Performance Certificate

17, Windrush Close, Bramley, GU5 0BB

EPC Report

Energy rating

Current: 68 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 62 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 83 Potential: 83
Field Value
LMK KEY 2798-1085-7285-7600-1234
ADDRESS1 17, Windrush Close
ADDRESS2 Bramley
ADDRESS3
POSTCODE GU5 0BB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-05-21
LOCAL AUTHORITY E07000216
CONSTITUENCY E14001249
COUNTY
LODGEMENT DATE 2020-05-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 203
ENERGY CONSUMPTION POTENTIAL 80
CO2 EMISSIONS CURRENT 4.7
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 89
HEATING COST CURRENT 744
HEATING COST POTENTIAL 510
HOT WATER COST CURRENT 158
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 131
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17, Windrush Close, Bramley
LOCAL AUTHORITY LABEL Waverley
CONSTITUENCY LABEL Godalming and Ash
POSTTOWN GUILDFORD
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2020-05-21 23:44:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100061626336
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew