Energy Performance Certificate

10, Norman Grove, LS5 3JH

EPC Report

Energy rating

Current: 9 G | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 9 G Current: 9 G 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 22 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 85 Potential: 85
Field Value
LMK KEY 2798-1068-7253-7210-0244
ADDRESS1 10, Norman Grove
ADDRESS2
ADDRESS3
POSTCODE LS5 3JH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 9
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2020-07-21
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001319
COUNTY
LODGEMENT DATE 2020-07-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 673
ENERGY CONSUMPTION POTENTIAL 95
CO2 EMISSIONS CURRENT 9.3
CO2 EMISS CURR PER FLOOR AREA 114
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 2669
HEATING COST POTENTIAL 412
HOT WATER COST CURRENT 442
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 82
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10, Norman Grove
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds Central and Headingley
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2020-07-21 16:37:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 72143040
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000003
Address display
Nation ew