Energy Performance Certificate

52 Fairfax Court, Acomb Road, YO24 4HS

EPC Report

Energy rating

Current: 77 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 68 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 71 Potential: 71
Field Value
LMK KEY 2788-0024-7221-3395-3920
ADDRESS1 52 Fairfax Court
ADDRESS2 Acomb Road
ADDRESS3
POSTCODE YO24 4HS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-09-28
LOCAL AUTHORITY E06000014
CONSTITUENCY E14001604
COUNTY
LODGEMENT DATE 2015-09-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 261
ENERGY CONSUMPTION POTENTIAL 234
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 197
HEATING COST POTENTIAL 163
HOT WATER COST CURRENT 156
HOT WATER COST POTENTIAL 128
TOTAL FLOOR AREA 53
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH 0
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 52 Fairfax Court, Acomb Road
LOCAL AUTHORITY LABEL York
CONSTITUENCY LABEL York Central
POSTTOWN YORK
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2015-09-28 16:59:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 200001900062
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew