Energy Performance Certificate

47 Carlton Road, NN2 7DQ

EPC Report

Energy rating

Current: 96 A | Potential: 98 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 96 A Current: 96 A 98 A Potential: 98 A

Environmental impact (CO₂)

Current: 95 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 95 Current: 95 97 Potential: 97
Field Value
LMK KEY 2771-3017-4306-0712-7204
ADDRESS1 47 Carlton Road
ADDRESS2
ADDRESS3
POSTCODE NN2 7DQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 96
POTENTIAL ENERGY EFFICIENCY 98
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-06-23
LOCAL AUTHORITY E06000062
CONSTITUENCY E14001406
COUNTY
LODGEMENT DATE 2022-06-23
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 95
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 22
ENERGY CONSUMPTION POTENTIAL 7
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 5
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 286
HEATING COST POTENTIAL 286
HOT WATER COST CURRENT 93
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 77
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.49 W/m²K
FLOOR ENERGY EFF Poor
FLOOR ENV EFF Poor
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.22 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.10 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.71
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 47 Carlton Road
LOCAL AUTHORITY LABEL West Northamptonshire
CONSTITUENCY LABEL Northampton North
POSTTOWN NORTHAMPTON
CONSTRUCTION AGE BAND 2021
LODGEMENT DATETIME 2022-06-23 17:52:50
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 15031504
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2022.csv
COUNTRY England
REGION E12000004
Address display
Nation ew