Energy Performance Certificate

61 The Parade, DY1 3JA

EPC Report

Energy rating

Current: 16 G | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 G Current: 16 G 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 11 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 Current: 11 64 Potential: 64
Field Value
LMK KEY 2731-3017-0206-1452-7204
ADDRESS1 61 The Parade
ADDRESS2
ADDRESS3
POSTCODE DY1 3JA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 16
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-06-27
LOCAL AUTHORITY E08000027
CONSTITUENCY E14001204
COUNTY
LODGEMENT DATE 2022-06-27
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 11
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 632
ENERGY CONSUMPTION POTENTIAL 167
CO2 EMISSIONS CURRENT 30
CO2 EMISS CURR PER FLOOR AREA 115
CO2 EMISSIONS POTENTIAL 8.2
LIGHTING COST CURRENT 207
LIGHTING COST POTENTIAL 146
HEATING COST CURRENT 4836
HEATING COST POTENTIAL 1558
HOT WATER COST CURRENT 458
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 262
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA More Than Typical
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.76
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 61 The Parade
LOCAL AUTHORITY LABEL Dudley
CONSTITUENCY LABEL Dudley
POSTTOWN DUDLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-06-27 14:05:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 90028367
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display
Nation ew