Energy Performance Certificate

6 Culver Park, SA70 7ED

EPC Report

Energy rating

Current: 42 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 33 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 60 Potential: 60
Field Value
LMK KEY 2722-4120-3129-5445-3071
ADDRESS1 6 Culver Park
ADDRESS2
ADDRESS3
POSTCODE SA70 7ED
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-11-08
LOCAL AUTHORITY W06000009
CONSTITUENCY W07000100
COUNTY
LODGEMENT DATE 2024-11-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 491
ENERGY CONSUMPTION POTENTIAL 271
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 4.7
LIGHTING COST CURRENT 141
LIGHTING COST POTENTIAL 141
HEATING COST CURRENT 2383
HEATING COST POTENTIAL 1631
HOT WATER COST CURRENT 524
HOT WATER COST POTENTIAL 269
TOTAL FLOOR AREA 103
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.72
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Culver Park
LOCAL AUTHORITY LABEL Pembrokeshire
CONSTITUENCY LABEL Mid and South Pembrokeshire
POSTTOWN TENBY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-11-21 13:52:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100100294225
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew