Energy Performance Certificate

29 MORIN ROAD, PRESTON, TQ3 2PN

EPC Report

Energy rating

Current: 19 G | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 G Current: 19 G 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 22 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 77 Potential: 77
Field Value
LMK KEY 2711-5135-8432-2198-0271
ADDRESS1 29 MORIN ROAD
ADDRESS2 PRESTON
ADDRESS3
POSTCODE TQ3 2PN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 19
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-03-24
LOCAL AUTHORITY E06000027
CONSTITUENCY E14001551
COUNTY
LODGEMENT DATE 2021-04-06
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 515
ENERGY CONSUMPTION POTENTIAL 107
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 87
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 146
LIGHTING COST POTENTIAL 123
HEATING COST CURRENT 3467
HEATING COST POTENTIAL 791
HOT WATER COST CURRENT 797
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 185
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric, Room heaters, mains gas
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.764
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29 MORIN ROAD, PRESTON
LOCAL AUTHORITY LABEL Torbay
CONSTITUENCY LABEL Torbay
POSTTOWN PAIGNTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-04-06 18:12:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100040529025
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000009
Address display