Energy Performance Certificate
27 Chesswick Avenue, Keadby, DN17 3DF
Energy rating
Current: 30 F | Potential: 72 C
Environmental impact (CO₂)
Current: 5
| Potential: 103
| Field | Value |
|---|---|
| LMK KEY | 2711-1112-8412-1237-9153 |
| ADDRESS1 | 27 Chesswick Avenue |
| ADDRESS2 | Keadby |
| ADDRESS3 | — |
| POSTCODE | DN17 3DF |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 30 |
| POTENTIAL ENERGY EFFICIENCY | 72 |
| PROPERTY TYPE | House |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2024-05-09 |
| LOCAL AUTHORITY | E06000013 |
| CONSTITUENCY | E14001199 |
| COUNTY | — |
| LODGEMENT DATE | 2024-05-13 |
| TRANSACTION TYPE | None of the above |
| ENVIRONMENT IMPACT CURRENT | 5 |
| ENVIRONMENT IMPACT POTENTIAL | 103 |
| ENERGY CONSUMPTION CURRENT | 504 |
| ENERGY CONSUMPTION POTENTIAL | 184 |
| CO2 EMISSIONS CURRENT | 14 |
| CO2 EMISS CURR PER FLOOR AREA | 176 |
| CO2 EMISSIONS POTENTIAL | -0.3 |
| LIGHTING COST CURRENT | 111 |
| LIGHTING COST POTENTIAL | 111 |
| HEATING COST CURRENT | 2459 |
| HEATING COST POTENTIAL | 1740 |
| HOT WATER COST CURRENT | 418 |
| HOT WATER COST POTENTIAL | 193 |
| TOTAL FLOOR AREA | 78 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | No time or thermostatic control of room temperature |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | not defined |
| GLAZED AREA | Much More Than Typical |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 6 |
| NUMBER HEATED ROOMS | 6 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Very Poor |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, filled cavity |
| WALLS ENERGY EFF | Average |
| WALLS ENV EFF | Average |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, smokeless fuel |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | No time or thermostatic control of room temperature |
| MAINHEATC ENERGY EFF | Very Poor |
| MAINHEATC ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | smokeless coal |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.48 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 27 Chesswick Avenue, Keadby |
| LOCAL AUTHORITY LABEL | North Lincolnshire |
| CONSTITUENCY LABEL | Doncaster East and the Isle of Axholme |
| POSTTOWN | SCUNTHORPE |
| CONSTRUCTION AGE BAND | England and Wales: 1930-1949 |
| LODGEMENT DATETIME | 2024-05-13 07:20:56 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 11 |
| UPRN | 100050199899 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2024.csv |
| COUNTRY | England |
| REGION | E12000003 |
| Address display | — |
| Nation | ew |