Energy Performance Certificate

20 Bidders Close, Stoke Fleming, TQ6 0NZ

EPC Report

Energy rating

Current: 44 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 49 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 56 Potential: 56
Field Value
LMK KEY 2700-5082-0122-4100-3623
ADDRESS1 20 Bidders Close
ADDRESS2 Stoke Fleming
ADDRESS3
POSTCODE TQ6 0NZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-06-08
LOCAL AUTHORITY E07000044
CONSTITUENCY E14001484
COUNTY
LODGEMENT DATE 2022-06-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 256
ENERGY CONSUMPTION POTENTIAL 195
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 103
HEATING COST CURRENT 1546
HEATING COST POTENTIAL 820
HOT WATER COST CURRENT 426
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 131
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20 Bidders Close, Stoke Fleming
LOCAL AUTHORITY LABEL South Hams
CONSTITUENCY LABEL South Devon
POSTTOWN DARTMOUTH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2022-06-08 10:51:07
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100040274015
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew