Energy Performance Certificate

4 Swan Cottages, Sowerby Road, Sowerby, PR3 0TT

EPC Report

Energy rating

Current: 18 G | Potential: 100 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 100 A Potential: 100 A

Environmental impact (CO₂)

Current: 30 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 75 Potential: 75
Field Value
LMK KEY 2628-8024-6226-6401-2944
ADDRESS1 4 Swan Cottages
ADDRESS2 Sowerby Road
ADDRESS3 Sowerby
POSTCODE PR3 0TT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 100
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-06-22
LOCAL AUTHORITY E07000128
CONSTITUENCY E14001318
COUNTY
LODGEMENT DATE 2019-06-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 542
ENERGY CONSUMPTION POTENTIAL 167
CO2 EMISSIONS CURRENT 8.6
CO2 EMISS CURR PER FLOOR AREA 92
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 2367
HEATING COST POTENTIAL 809
HOT WATER COST CURRENT 372
HOT WATER COST POTENTIAL 114
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Swan Cottages, Sowerby Road, Sowerby
LOCAL AUTHORITY LABEL Wyre
CONSTITUENCY LABEL Lancaster and Wyre
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2019-06-22 19:30:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 200001130427
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000002
Address display
Nation ew