Energy Performance Certificate

3 OTTERBURN CRESCENT, SUNDERLAND, HOUGHTON LE SPRING, DH4 5HT

EPC Report

Energy rating

Current: 28 F | Potential: 65 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 F Current: 28 F 65 D Potential: 65 D

Environmental impact (CO₂)

Current: 26 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 55 Potential: 55
Field Value
LMK KEY 2628-3000-2201-0650-0204
ADDRESS1 3 OTTERBURN CRESCENT
ADDRESS2 SUNDERLAND
ADDRESS3 HOUGHTON LE SPRING
POSTCODE DH4 5HT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 28
POTENTIAL ENERGY EFFICIENCY 65
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2020-09-22
LOCAL AUTHORITY E08000024
CONSTITUENCY E14001295
COUNTY
LODGEMENT DATE 2020-09-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 469
ENERGY CONSUMPTION POTENTIAL 216
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 5.0
LIGHTING COST CURRENT 118
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 1738
HEATING COST POTENTIAL 1031
HOT WATER COST CURRENT 493
HOT WATER COST POTENTIAL 216
TOTAL FLOOR AREA 104
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 OTTERBURN CRESCENT, SUNDERLAND, HOUGHTON LE SPRING
LOCAL AUTHORITY LABEL Sunderland
CONSTITUENCY LABEL Houghton and Sunderland South
POSTTOWN HOUGHTON-LE-SPRING
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2020-09-20 15:21:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 45091735
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000001
Address display
Nation ew