Energy Performance Certificate

23a Bicester Park Homes, Oxford Road, OX25 2NY

EPC Report

Energy rating

Current: 46 E | Potential: 50 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 50 E Potential: 50 E

Environmental impact (CO₂)

Current: 64 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 67 Potential: 67
Field Value
LMK KEY 2625-1310-1981-2257-7114
ADDRESS1 23a Bicester Park Homes
ADDRESS2 Oxford Road
ADDRESS3
POSTCODE OX25 2NY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 50
PROPERTY TYPE Park home
BUILT FORM Detached
INSPECTION DATE 2024-05-29
LOCAL AUTHORITY E07000177
CONSTITUENCY E14001090
COUNTY
LODGEMENT DATE 2024-05-29
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 218
ENERGY CONSUMPTION POTENTIAL 200
CO2 EMISSIONS CURRENT 3
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 153
LIGHTING COST POTENTIAL 98
HEATING COST CURRENT 1285
HEATING COST POTENTIAL 1204
HOT WATER COST CURRENT 340
HOT WATER COST POTENTIAL 340
TOTAL FLOOR AREA 71
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 43
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Park home wall, with external insulation
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, LPG, Air source heat pump, warm air, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 43% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL bottled LPG
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.25
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23a Bicester Park Homes, Oxford Road
LOCAL AUTHORITY LABEL Cherwell
CONSTITUENCY LABEL Bicester and Woodstock
POSTTOWN BICESTER
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2024-05-29 16:30:31
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10011929637
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display