Energy Performance Certificate

11, Tylney Road, E7 0LS

EPC Report

Energy rating

Current: 4 G | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 4 G Current: 4 G 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 19 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 Current: 19 84 Potential: 84
Field Value
LMK KEY 2588-7017-7239-2495-1964
ADDRESS1 11, Tylney Road
ADDRESS2
ADDRESS3
POSTCODE E7 0LS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 4
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-01-28
LOCAL AUTHORITY E09000025
CONSTITUENCY E14001525
COUNTY
LODGEMENT DATE 2015-01-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 19
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 573
ENERGY CONSUMPTION POTENTIAL 65
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 127
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 2309
HEATING COST POTENTIAL 421
HOT WATER COST CURRENT 526
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 107
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.83
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Tylney Road
LOCAL AUTHORITY LABEL Newham
CONSTITUENCY LABEL Stratford and Bow
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-01-28 20:26:56
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 46075638
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew