Energy Performance Certificate

39 The Baulk, SG18 0PX

EPC Report

Energy rating

Current: 65 D | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 57 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 66 Potential: 66
Field Value
LMK KEY 2578-9068-7337-4566-6984
ADDRESS1 39 The Baulk
ADDRESS2
ADDRESS3
POSTCODE SG18 0PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-03-23
LOCAL AUTHORITY E06000056
CONSTITUENCY E14001384
COUNTY
LODGEMENT DATE 2016-08-17
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 231
ENERGY CONSUMPTION POTENTIAL 176
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 927
HEATING COST POTENTIAL 927
HOT WATER COST CURRENT 110
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 124
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 4
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION ²K
FLOOR ENERGY EFF Poor
FLOOR ENV EFF Poor
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION ²K
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION ²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 0.0
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 39 The Baulk
LOCAL AUTHORITY LABEL Central Bedfordshire
CONSTITUENCY LABEL North Bedfordshire
POSTTOWN BIGGLESWADE
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2016-08-17 16:10:14
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 200001667814
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew