Energy Performance Certificate

21 Middleham Road, Houghton Conquest, MK45 3TL

EPC Report

Energy rating

Current: 94 A | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 A Current: 94 A 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 91 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 91 Potential: 91
Field Value
LMK KEY 2575-3009-1306-7425-9200
ADDRESS1 21 Middleham Road
ADDRESS2 Houghton Conquest
ADDRESS3
POSTCODE MK45 3TL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 94
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-06-23
LOCAL AUTHORITY E06000055
CONSTITUENCY E14001359
COUNTY
LODGEMENT DATE 2025-06-23
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 46
ENERGY CONSUMPTION POTENTIAL 46
CO2 EMISSIONS CURRENT 1.2
CO2 EMISS CURR PER FLOOR AREA 8.8
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 369
HEATING COST POTENTIAL 369
HOT WATER COST CURRENT 155
HOT WATER COST POTENTIAL 155
TOTAL FLOOR AREA 138
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.19 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.1 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Excelent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 21 Middleham Road, Houghton Conquest
LOCAL AUTHORITY LABEL Bedford
CONSTITUENCY LABEL Mid Bedfordshire
POSTTOWN Bedford
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2025-06-23 13:40:20
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 26
UPRN 10096282187
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew