Energy Performance Certificate

35 Wesco Court, Board School Road, GU21 5HH

EPC Report

Energy rating

Current: 58 D | Potential: 62 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 62 D Potential: 62 D

Environmental impact (CO₂)

Current: 50 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 55 Potential: 55
Field Value
LMK KEY 2553-3042-2201-8024-4200
ADDRESS1 35 Wesco Court
ADDRESS2 Board School Road
ADDRESS3
POSTCODE GU21 5HH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 62
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2024-09-25
LOCAL AUTHORITY E07000217
CONSTITUENCY E14001592
COUNTY
LODGEMENT DATE 2024-09-30
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 381
ENERGY CONSUMPTION POTENTIAL 341
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 964
HEATING COST POTENTIAL 848
HOT WATER COST CURRENT 185
HOT WATER COST POTENTIAL 185
TOTAL FLOOR AREA 49
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35 Wesco Court, Board School Road
LOCAL AUTHORITY LABEL Woking
CONSTITUENCY LABEL Woking
POSTTOWN WOKING
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-09-30 09:25:55
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100062168029
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew